Stress tracking on wearables like the Fitbit Sense usually relies on electrodermal activity, or EDA. The method measures changes in skin conductance caused by sweat glands, but it needs electrodes to stay in steady contact with your skin. But there are a few drawbacks to this approach. You need to place your hand over the wearable to enable skin contact, and keep it that way for a couple of minutes. That also means every time you want to check stress levels, you need to take a break and perform the sensing exercise because it doesn’t perform continuous stress monitoring.
We may finally have an entirely new approach to stress-sensing that uses light-based analysis for a more accurate analysis, and something with a framework so frugal that the whole chore can run entirely on the ring itself. Plus, it’s continuous stress level monitoring, just like heart rate sensing, which means you don’t have to strike a pose or take any extra effort other than simply wearing a ring. A University of Southern California team led by assistant professor Yasser Khan and his PhD student Farhad Hassan built an AI-powered ring that uses near-infrared light to track sweat activity beneath the skin. Their findings were published in Science Advances.
Two beams of light handle the sweat sensing

Stress activates your sweat glands and causes subtle changes under the skin before visible sweat appears. “Our idea is very simple. We want to look at this small sweat under the skin with light,” Khan said. The ring uses two near-infrared LEDs to spot these changes. One shines at 960 nanometers and reacts to shifts in water content linked to sweat. The other works at 1,250 nanometers and acts as a stable reference. The researchers call this approach optodermal activity, or ODA.
“This is the first time that someone is showing that stress can be measured with light,” Khan said. In experiments with four participants, the optical signals showed an average 86 percent agreement over time with a commercial gel-based EDA sensor. The same optical system also captures heart rate and heart rate variability. A temperature sensor and accelerometer help the ring tell psychological stress apart from movement or heat-induced sweating.
The ring held up better than gel sensors over 12 hours

In short-term tests with six participants, the ring distinguished stress from relaxation 92.3 percent of the time, compared with 77.95 percent for the gel-based EDA sensor. When the test expanded to four conditions of stress (relaxation, physical movement, and heat-induced sweating), the ring reached 100 percent accuracy compared with 74.58 percent for EDA. After 12 hours of wear tested with two participants, the gel-based sensor’s accuracy in distinguishing stress from relaxation fell to 57.35 percent, while the ODA ring held at 79.55 percent.
The machine-learning model also runs on the ring itself, so raw biometric data does not have to travel to an outside server. This cuts delays and keeps sensitive personal data on the ring, according to the USC announcement. Khan plans a yearlong follow-up with 40 participants in an office setting. The researchers are also working to reduce interference from heavy surface sweat and to test a broader mix of cognitive and psychosocial stressors. The technology is in the patent process and may later be offered for commercial licensing through USC’s Stevens Center for Innovation.
A bright outlook for the future

The most promising element about the ring is that it uses off-the-shelf components that are easily available. Additionally, most of the sensors used in the project, such as a temperature sensor and an accelerometer, are already widely deployed on mainstream devices such as the RingConn Gen 3 smart ring. The standout hardware element is the light source, which targets different wavelengths compared to the usual LED array on a commercially available smart ring.
Specifically, the team equipped the ODA ring with a 960-nm stress-sensing and a 1250-nm baseline-sensing light-emitting diode (LED), paired with dual photodiodes. Aside from tracking sweat gland activity, the same optical setup also allows the ring to capture biomarkers such as pulse amplitude (PA), heart rate (HR), and their variabilities (PAV and HRV). Heart rate and HRV, in particular, are also tracked by mainstream wearables for monitoring heart activity and stress.
The team notes that the approach isn’t limited to rings. On the contrary (and thankfully), it can be scaled to other wearable form factors as well. “The optical sensing demonstrated here is scalable and applicable to noninvasive wearables in ring, watch, and patch form factors,” the team writes in their paper published in the Science Advances journal. Beyond the raw hardware capabilities, the team also showed that the algorithm powering the sweat-based biosensing system is fairly modest in its requirements.
“The quantized INT8 model occupied 27.65 kB. Simultaneous sensing and inference implementation required 174.47 kB of program flash and 27.63 kB of static RAM,” writes the team. In other words, the AI model is small enough to run entirely on the ring’s own microcontroller. That’s what edge AI means here. Instead of streaming raw sensor data to a phone or a cloud server for analysis, the ring processes it locally and only sends the final verdict, such as stressed or relaxed, to the paired phone.

According to the paper, this approach cut the post-sensing delay by roughly 300 times, from 9.9 seconds to send raw data over Bluetooth down to about 33 milliseconds for on-device inference. It also stretched continuous battery life from about 4.2 hours to 6 hours. Just as importantly, sensitive physiological data never has to leave the ring, which is a huge privacy win at a time when health data is increasingly being sent to the cloud.
Furthermore, even if a more advanced version were to offload processing to a phone, a model this small would barely register on modern hardware. Today’s flagship smartphones can already run AI models with a few billion parameters locally, so a stress-sensing model that needs well under 1MB of memory would be trivial for them to handle. Overall, this is one of the more scientifically mature and reliable methods of wearable-based sensing than making approximations using HRV readings.
RELATED COVERAGE: